        特氣/安全

        霍尼韋爾偵測器,MIDAS-S-SO2, MIDAS-E-SO2
        • 霍尼韋爾偵測器,MIDAS-S-SO2, MIDAS-E-SO2

        • MIDAS Sulphur
          Dioxide (SO2)
          MIDAS-S-SO2, MIDAS-E-SO2

        MIDAS Sulphur
        Dioxide (SO2)
        MIDAS-S-SO2, MIDAS-E-SO2

        ?

        霍尼韋爾偵測器,MIDAS-S-SO2, MIDAS-E-SO2

        霍尼韋爾偵測器,MIDAS-S-SO2, MIDAS-E-SO2

        霍尼韋爾偵測器,MIDAS-S-SO2, MIDAS-E-SO2

        ?

        Gas Measured Sulphur Dioxide (SO2)
        CARTRIDGE PART NUMBER
        SENSOR TECHNOLOGY 3 electrode electrochemical cell
        MIDAS-S-SO2 1 year standard warranty
        MIDAS-E-SO2 2 year extended warranty
        MEASURING RANGE (PPM) SO2 0 – 8ppm
        MINIMUM ALARM 1 SET POINT 1.00ppm
        REPEATABILITY < ± 2% of measured value
        RESPONSE TIME T62.5 < 5 seconds
        SENSOR CARTRIDGE LIFE EXPECTANCY  24 months under typical application
        conditions
        OPERATING TEMPERATURE
        EFFECT OF TEMPERATURE
        SENSITIVITY
        0oC to +40oC (32oF to 104oF)
        < ± 0.003ppm / oC (0oC to 20oC)
        < ± 0.03ppm / oC (20oC to 40oC)
        < ± 0.4% of measured value / oC
        OPERATING PRESSURE 90 - 110 kPa
        EFFECT OF POSITION No effect in typical application
        LONG TERM DRIFT
        ZERO
        SENSITIVITY
        TBA
        < ± 2% of measured value / year
        CALIBRATION GAS Sulphur Dioxide (SO2)
        CHALLENGE GAS (BUMP TEST) Sulphur Dioxide (SO2)
        WARM UP TIME < 10 minutes
        STORAGE TEMPERATURE +5°C to +25°C (+41°F to +77°F)
        The sensor data listed is based on ideal test environment;
        observed performance may vary based on the actual monitoring
        system and the sampling conditions employed

        ?

        交叉敏感問題

        每個Midas?傳感器可能對其他氣體交叉敏感

        當接觸到其他氣體時,這可能會導致氣體讀數

        比原來指定的要多。下表展示了

        使用新傳感器時觀察到的典型讀數

        藥筒暴露在交叉敏感氣體中

        (或含有交叉敏感物種的氣體混合物)。